Knutsson, Karl Anders and Genovese, Paola Noemi and Paganoni, Giorgio and Ambrosio, Oriella and Ferrari, Giulio and Zennato, Arianna and Caccia, Michela and Cataldo, Madeleine and Rama, Paolo (2023) Safety and Efficacy of Corneal Cross-Linking in Patients Affected by Keratoconus: Long-Term Results. Medical Sciences, 11 (2). p. 43. ISSN 2076-3271
medsci-11-00043-v2.pdf - Published Version
Download (705kB)
Abstract
The present study evaluated the effectiveness and safety of corneal collagen cross-linking (CXL). A total of 886 eyes with progressive keratoconus were enrolled in a retrospective cohort study in a tertiary care university hospital. CXL was performed using a standard epithelium-off Dresden protocol. Visual outcomes, maximum keratometry (Kmax), demarcation line measurements, and complications were recorded. Visual outcomes and keratometric data were analyzed in a subgroup comprising 610 eyes. Uncorrected distance visual acuity (UDVA) improved from 0.49 ± 0.38 LogMAR to 0.47 ± 0.39 LogMAR (p = 0.03, n = 610) three years after the procedure, while corrected distance visual acuity (CDVA) improved from 0.15 ± 0.14 LogMAR to 0.14 ± 0.15 LogMAR (p = 0.007, n = 610). A significant reduction of Kmax from 56.28 ± 6.10 to 54.98 ± 6.19 (p < 0.001, n = 610) was observed three years after CXL. In five eyes (0.82%, 5/610) keratoconus progression continued after CXL. Three eyes were retreated successfully with documented refractive and topographic stability after five years. In the 35 eyes that completed 10 years of follow-up, mean visual acuity and topographic parameters remained stable. In conclusion, CXL is a safe and effective treatment for avoiding keratoconus progression. Long-term data are encouraging, supporting a high safety profile for this procedure.
Item Type: | Article |
---|---|
Subjects: | Universal Eprints > Medical Science |
Depositing User: | Managing Editor |
Date Deposited: | 07 Oct 2023 09:16 |
Last Modified: | 07 Oct 2023 09:16 |
URI: | http://journal.article2publish.com/id/eprint/2630 |